CFL Reflector Products Technology Procurement

Elevated Temperature Life Testing (ETLT) Final Test Results

Average Lumen Maintenance

Average lumen output measurement of the 10 lamps tested per model must be greater than 90% of initial (100 hour) lumen output at 1000 hours (measurement error of -3%).

Phase 2 Batch 1

Test results show the overall average lumen maintenance for 10 models (10 samples each) in elevated temperature life testing (ETLT) as of 10,281.6+ hours (10/01/07). This is an aggregate report of lumen maintenance, expressed as a percentage, for all samples subjected to Elevated Temperature Life Testing.

Phase 2 Batch 2

Test results show the overall average lumen maintenance for 13 models (10 samples each) in ETLT as of 8,294.4 hours (10/01/07). This is an aggregate report of lumen maintenance, expressed as a percentage, for all samples subjected to Elevated Temperature Life Testing.

Average Rated Life

R-CFL models moved into ETLT were subjected to a minimum of 6,000 hours of testing to determine their Average Rated Life. Average Rated Life is defined as the point at which 50% of the lamp models in testing are still operating.

Phase 2 Batch 1

Test results show the failed / still operating status for each of the 10 R-CFL models subjected to ETLT as of 10,281.6 hours (10/01/07).

Phase 2 Batch 2

Test results show the failed / still operating status for each of the 13 R-CFL models subjected to ETLT as of 8,294.4 hours (10/01/07).